Showing results: 136 - 150 of 257 items found.
-
MeasureReady™ 155 -
Lake Shore Cryotronics, Inc.
The MeasureReady™ 155 Precision I/V source combines premium performance with unprecedented simplicity for materials scientists and engineers requiring a precise source of current and voltage. Low RMS noise: from 200 nV (10 mV)/7 pA (1 µA). Bipolar, 4-quadrant power source. DC and AC modes supported up to 100 kHz*. Full scale ranges from 10 mV to 100 V (1 μA to 100 mA). 0.001% programming resolution (from 100 nV/10 pA.
-
COSMOS™ -
Teledyne Princeton Instruments
The COSMOS™ is the only large format, high performance CMOS camera designed and manufactured entirely within a single source. With LACera™ technology, the COSMOS offers superior sensitivity, large imaging area, low noise and fast frame rate.
-
Dewesoft d.o.o.
Sound Intensity MeasurementA perfect tool for sound intensity level measurement and noise source determination brought to an entirely new level by Dewesoft. The solution brings a simple and intuitive measurement process while offering the utmost precision and industry unmatched adaptability.
-
Boonton Electronics
Audio analyzer provides fast, accurate measurements including frequency, AC or DC level, distortion, SINAD and signal-to-noise ratio. It also includes an audio source providing accurate low distortion signals over wide frequencies and level ranges.
-
MSXB 085 -
Microstar Laboratories, Inc.
The MSXB 085 Isolated Analog Expansion Board provides isolated analog inputs and isolated analog outputs for DAP systems. Use these boards to eliminate ground currents – a potential source of noise in your measurement and control signals – and eliminate timing skew.
-
Analog Devices Inc.
Analog Devices’ current source D/A converters (DACs) portfolio is ideal for photonics control applications where low current noise density, low dropout voltage, and high power efficiency, in addition to high channel density, is critical to system performance. The flexibility of the configurable current source D/A converter outputs, and 300 mA current delivery, make them suitable for resistive heaters and proportional solenoid drive.
-
Noisecom
The Noisecom 60 GHz Noise Figure test set has 4 separate systems designed to perform Y-factor noise figure measurements using a high performance Spectrum Analyzer or a dedicated receiver. Each system contains a highly stable V-band noise source, isolator(s), optional waveguide to coaxial transitions and an optional pre-amplifier for use with a spectrum analyzer. The two standard calibration tables have ENR data points at 1 GHz intervals.* System ENR is measured before the DUT connector and at the final output stage allowing for pre-test calibration of the system.
-
100 / 101 -
Lake Shore Cryotronics, Inc.
The Models 100 and 101 are battery-powered DC current sources which provide a very stable output current without the noise commonly associated with AC line-powered instruments. They are well-suited for field maintenance and periodic monitoring of sensors, as well as operation in a highly noise-sensitive environment.
-
VCH-325 -
VREMYA-CH JS Company
Comparator-analyzer phase digital VCH-325, designed for precision measurements of the relative frequency difference, frequency instability and phase noise spectrum of highly stable signal sources in the frequency range from 1 to 100 MHz. The software is installed on an external computer (computer not included).
-
BAS003 -
Larson Davis, Inc.
The BAS003 Source is designed to generate homogeneous sound fields using random noise in compliance with the following standards: Building acoustics (insertion loss, acoustic absorption area, etc: ISO 140-3, ASTM E90, ISO 140-5, ASTM E966). The BAS003 is typically used to generate a noise in a free-field for the evaluation of the transmission loss index of a façade. The available high-efficiency power amplifier, BAS002, is light and can be remotely controlled for easy use in the field.
-
STM-1 -
ECO-TECH
Tapping Machine Type STM-1 is intended for measurements of acoustic insulation of ceiling in buildings. The unit fulfils Annex A of ISO 140-6/7. These parts of the standard require a tapping machine as a sound source for impact noise measurements. Type STM-1 is available with an optional remote control.
-
1121A -
Boonton Electronics
The Model 1121A audio analyzer provides fast, accurate measurements including frequency, AC or DC level, distortion, SINAD and signal-to-noise ratio. It also includes an audio source providing accurate low distortion signals over wide frequencies and level ranges.
-
Laplace Instruments Ltd.
EMC emissions can be at very low signal levels and pre-amplifiers can help to improve S/N ratio. The low level of emission signals can make them difficult to identify in noisy environments. RF filters are designed to attenuate the major sources of noise, thus making the task of measurement easier.
-
EMC Instruments Corporation
The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators
-
EMC Instruments Corporation
The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators